    National Grid Distribution System AAAC Conductor

    Ask Lasest Price
    Brand Name : Sanwu
    Model Number : AAC
    Certification : ISO CCC
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 200 tons per day
    Delivery Time : 1-15days
    MOQ : 10KM
    • Product Details
    • Company Profile

    National Grid Distribution System AAAC Conductor

    National Grid Distribution System AAAC Conductor All Aluminum Alloy Conductor Aluminum Cable


    AAC All Aluminum Conductor


    Application

    AAC–ASTM-B All Aluminium Conductor
    AAC are a refined Aluminium stranded conductor with a minimum metal purity of 99.7%. It is principally used in urban areas where spacing is short and the supports are close. It can be used in coastal regions owing to its high degree of corrosion resistance and is also used extensively within the Railway and Metro industries.



    Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost, large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

    2. Service Performance

    (1).The permissible long-time operating temperature for aerial conductor is 70oC.

    (2).Under the circumstance that rare climate occurs and high ice coverage rate, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.

    (3).When connecting conductors, the conductor beside the connecting tube can’t be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are installed, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.

    (4).Under installation, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.

    We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

    Nominal

    area

    Stranding &wire diameterApprox Overall diameterBreaking LoadDC Resistance at 20

    Approx.

    Weight

    mmmmNΩ/kmKg/km
    167/1.705.1028401.80243.5
    257/2.156.4543551.12769.6
    357/2.507.5057600.833294.1
    507/3.009.0079300.5786135..5
    707/3.6010.80109500.4018195.1
    957/4.1612.48144500.3009260.5
    12019/2.8514.25194200.2373333.5
    15019/3.1515.75233100.1943407.4
    18519/3.5017.5284400.1574503.0
    21019/3.7518.75322600.1371577.4
    24019/4.0020.00362600.1205656.9
    30037/3.2022.40468500.09689820.4
    40037/3.7025.90611500.072471097
    50037/4.1629.12763700.057331387
    63061/3.6332.67919400.045771744
    80061/4.1036.901159000.035882225